Optech Sentinel 3000

The Sentinel series of continuous non-contact level monitors is used to monitor material levels under a wide range of process conditions, from the simplest bin to the most demanding vessel application.

Features:

  • High-accuracy
  • Varying angles of response
  • Inferred readings
  • High temperature sightglasses are available

Specification:

  • AC/DC Power Supply
  • Input voltage: 120 VAC, 20 VA; 50-60 Hz
  • Operating temperature: -10° C to +50° C
  • Range:
    • Minimum range 0.2 m
    • Maximum range1 150 m
  • AC Heater7:
  • Input voltage: 120 VAC, 100 W
  • Operating temperature: -40° C to +50° C

Optech Sentry

Please call 1300 8877 35 to request a quote or for more information.

Optech Sentry SR

The Sentry SR Series of lasers are the latest in laser technology designed for both level and positioning applications. The Sentry SR operates up to 25 m and is housed in a rugged, explosion-proof enclosure.It has optimized for short-range applications (less than 25 m). Also available with a cooling plate option, extending operation to 150°C

Features:

  • Explosion-proof enclosure
  • Programmable discrete relays
  • Mounts to 2"-plus flanges
  • RS-232C and analog outputs
  • Easily programmable
  • CSA, CE, FM, approval
  • High-temperature options
  • Internal diagnostics

Specification

  • Power:
    • Input: 24 VDC, 110 VAC or 220 VAC
    • Consumption: @ 24 VDC 10 W (without heater) 101 W (with heater)
  • Size: 127 mm W x 305 mm L
  • Weight: 6.2 kg (13.5 lbs.)
  • Standard mounting Articulated bracket
  • Outputs:Analog3: 4-20 mA; max. load 1,200 ohms; 1,500
  • VDC isolation: Serial RS-232C bi-directional; for test and setup only; not isolated
  • Relays Programmable for range
  • (set/reset) or alarms