Chemistries                 1300 887 735

Stir Plate, TitraStir, 115 Vac

OBSOLETE ITEM

Stir Plate, TitraStir, 115 Vac
Product #: 1940000

OBSOLETE ITEM

Parameter/Range/Reagent Information

Acid-Base Method Range Reagent Set(s) USEPA Compliant?
  8200 (Acid) 1 - 10 meq/L View  
  8200 (Acid) 10 - 4,000 meq/L View  
  8233 (Base) 1 - 10 meq/L View  
  8233 (Base) 10 - 4,000 meq/L View  
Acidity Method Range Reagent Set(s) USEPA Compliant?
  8201 Methyl Orange Acidity 10 - 160 mg/L CaCO₃ View Y
  8202 Phenolphthalein (Total) Acidity 100 - 4,000 mg/L CaCO₃ View Y
Alkalinity Method Range Reagent Set(s) USEPA Compliant?
  8203 10 - 4,000 mg/L as CaCO₃ View Y
Carbon Dioxide Method Range Reagent Set(s) USEPA Compliant?
  8205 10 - 1,000 mg/L CO₂ View  
  8205 10 - 100 mg/L View  
  8233 0 - 250 mg/L CO₂ View  
Chelant Method Range Reagent Set(s) USEPA Compliant?
  8350 Total, Digital Titration Bismuth Nitrate 0 - 40.0 mg/L Na₄ EDTA View  
  8352 Free, Digital Titration Digital Titrator 0 - 20.0 mg/L CaCO₃ View  
Chloride Method Range Reagent Set(s) USEPA Compliant?
  8206 Digital Titration Mercuric Nitrate 10 - 8,000 mg/L Cl View Y
  8207 Digital Titration Silver Nitrate 10 - 10,000 mg/L Cl View  
  8207 Digital Titration Silver Nitrate 10 - 100 mg/L Cl View  
  8207 Digital Titration Silver Nitrate 100 - 10,000 mg/L Cl View  
Chlorine, Free Method Range Reagent Set(s) USEPA Compliant?
  10024 0 - 1,000 µg/L Cl₂ View Y
  8334 Amperometric Buret Titration Method 0.5 mg/L and above Cl₂ View Y
Chlorine, Free & Total Method Range Reagent Set(s) USEPA Compliant?
  8210 DPD-FEAS Digital Titrator 0 - 3.00 mg/L Cl₂ View  
Chlorine, Total Method Range Reagent Set(s) USEPA Compliant?
  10025 WAH, Digital Titration 6 - 1,000 µg/L Cl₂ View Y
  10026 WAH, Digital Titration Amperometric Forward Titration 15 - 1,000 µg/L Cl₂ View Y
  8168 Amperometric Buret Titration Method 0.0012 - 5,000 mg/L Cl₂ View Y
  8168 WAH, Amperometric Buret Titration 0.5 - mg/L and above View Y
  8209 Iodometric Method 2,000 - 70,000 mg/L CL₂ View  
  8209 Iodometric Method 20 - 2,000 mg/L Cl₂ View  
  8209 WAH, Iodometric, Digital Titration 1 - 400 mg/L Cl₂ View  
Chromate Method Range Reagent Set(s) USEPA Compliant?
  8211 20 - 400 mg/L CrO₄²- View  
Hardness Method Range Reagent Set(s) USEPA Compliant?
  8204 Calcium Hardness Digital Titration EDTA 10 - 4,000 mg/L as CaCO₃ View  
  8213 Digital Titration Digital Titration using EDTA 10 - 4,000 mg/L as CaCO₃ View  
  8213 Digital Titration Digital Titration using EDTA 100 - 4,000 mg/L CaCO3 View  
  8329 Digital Titration EDTA 10 - 160 mg/L CaCO3 View  
  8329 Digital Titration EDTA 10 - 4,000 mg/L CaCO3 View  
Iron Method Range Reagent Set(s) USEPA Compliant?
  8214 Digital Titration 10 - 100 mg/L Fe View  
  8214 Digital Titration 100 - 1,000 mg/L Fe View  
Nitrite Method Range Reagent Set(s) USEPA Compliant?
  8351 Digital Titration 100 - 2,500 mg/L NaNO₂ View