Evita OXY 4100 Dissolved Oxygen System Package 2

OBSOLETE ITEM

Evita OXY 4100 Dissolved Oxygen System Package 2
Product #: 085G4001

OBSOLETE ITEM

Simple Automatic Calibration

Calibration is done automatically by simply tilting the transmitter. It takes 5 minutes, three times a year.

Virtually Maintenance-Free

The Hach EVITA OXY Transmitter performs with less than 30 minutes of maintenance a year. The factory “all-inclusive” sensor contains electrolyte, membranes and electrodes.

There is no need for regeneration—simply replace
the sensor every two years and it’s done after 5 minutes.

Unique self-cleaning design—the spherical form and the
“fins” ensure that contaminants will not stick to the sensor. Forget all about immersed cleaning systems! Wipe the sensor down three times per year during normal calibration to ensure optimal performance.

Self-Contained and Highly Accurate

Hach’s EVITA OXY Transmitter is very accurate. An extremely accurate Pt 1000 temperature sensor ensures correct temperature compensation. Cartridges (factory-sealed or self-contained) are replaceable. No reuse of working parts, i.e. anodes and cathodes.

Versatile Configurations

The EVITA transmitter is available in three versions. Ball float style (model 4100), probe style (model 4150), and probe style specific to fish farming applications (model 3150).

Fish farming application available-call for details

What's included?

System package includes: USC 5000 signal converter, DO transmitter with 33 ft cable, membrane cartridge, mounting bracket and manual

Specifications

Accuracy: ± 0.5 % of reading
Accuracy: Analog Output: ± 0.2 % of FSO at calibrating temperature
Accuracy: Digital/Analogue Output: ± 0.5 % of FSO at 0 - 40 °C
Accuracy: Digital Output: ± 0.1 % of FSO at calibrating temperature
Accuracy 2: ± 0.5 °C of reading
Alarm: On current output (see section “Trouble shooting” of manual)
Altitude: max. 2000 m
Altitude 2: 2000 m
Ambient Temperature: -40 - 70 °C
Cable Length: 10 m 2-wire, screened cable 2 x 0.75 mm2 (18 AWG) cable
Calibration Method: Automatic air calibration compensating for temperature, barometric pressure, humidity and salinity by using the TILTCAL or the USC 5000
Communication: HART communication superposed on current output
Current Output: 4 to 20 mA (scalable by HART®) galvanic isolated. Max load 750 ohm@ 30 Vdc
Current Outputs Controller: 1 x 4 to 20 mA scaleable, 24 V active galvanic isolated, max. load: 800 Ω
Diameter: 240 mm
Diaphragm Leakage Monitoring: Measurement between anode and a terminal in contact with the measured medium
Display: Back-lit alphanumeric LCD display
Enclosure Rating: IP67 / NEMA 4X
Fuse Rating: Fuse: T500 mA / 250 V (not to be changed by user)
Material: Transmitter: PBT/PC
Measurement Range: Oxygen: ± 0.5 % of full scale
Measurement Range 2: 0 to 0.1 - 50 mg/L or ppm
Measurement Range 3: 0 - 200 % can be configured
Measuring Principle: Clark cell
Measuring Range Temperature: 0 - 70 °C
Measuring uncertainty: Temperature: ± 0.5 °C
Number of Channels: point-to-point installation
Power requirements (Voltage): 12 - 30 V DC
Range: 10 - 500 %
Relative Humidity: 80 %
  80 % at 31 °C (decreasing linearly to 50% at 40 °C)
Relays: 3 none
Response Time: 25 µm: time = 7 s
Response time: 50 µm: time = 22 s 22 s determined by EVITA OXY 1100
Special Notes: Composed of:
USC 5000, EVITA OXY 4100 transmitter (ball), 0-20 mg/l, 10 m cable
EVITA OXY 1100 sensor, 50 µm
mounting bracket for EVITA OXY
Time Constant: 10 - 300 s (default 40 s)
Weight: OXY 4100 Transmitter: 2 kg
Weight Transmitter: 2.7 kg
What's included?: System package includes: USC 5000 signal converter, DO transmitter with 33 ft cable, membrane cartridge, mounting bracket and manual