Chemistries                 1300 887 735

SC200 Universal Controller: 100-240 V AC (North America power cord) with one 4-20mA input, one analog conductivity sensor input, HART and two 4-20mA outputs

OBSOLETE ITEM

SC200 Universal Controller: 100-240 V AC (North America power cord) with one 4-20mA input, one analog conductivity sensor input, HART and two 4-20mA outputs
Product #: LXV404.99.55422

OBSOLETE ITEM

Maximum Versatility

• Standardized controller eliminates the need for a variety of dedicated controllers
• Multi-channel controller operates either 1 or 2 sensors reducing inventory holding costs, and providing an inexpensive option to add a second sensor at a later time
• "Plug and Play" operation with all Hach digital sensors
• True dual sensor controller provides 4-20 mA outputs to transmit primary and secondary measurement values

Ease of Use

• New display and guided calibration procedures reduce operator error
• Simple, intuitive user interface for navigating both sensor and controller options

Confidence in Results

• Password protected SD card reader offers a simple solution for data download and transfer
• Visual warning system provides critical alerts

One Controller, Numerous Communication Options

Hach offers the largest portfolio sensors and analyzers for water analytics with MODBUS RS232, MODBUS RS485, Profibus® DP, and HART capability.

Broadest Range of Sensors

Use the SC200 Universal Controller in combination with over 30 different sensor families covering 17 different parameters

What's included?

Controller, Mounting Hardware, Basic User Manual

Specifications

Analog Output Functional Mode: Linear, logarithmic, bi-linear, PID
Analog Outputs: Two (Five with optional expansion module) isolated current outputs, max 550 Ω, Accuracy:± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range
Operational Mode: measurement or calculated value
Communication: HART and two 4-20mA outputs
  Modbus RS232/RS485, Profibus
Communication Capabilities: HART
Conduit Openings: 1/2" NPT Conduit
Dimensions (H x W x D): 144 mm x 144 mm x 181 mm
Display: Graphic dot matrix LCD with LED backlighting, transreflective
Display Resolution: 240 x 160 pixels
Display Size: 48 x 68 mm
Electrical Certifications: EMC
CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Safety
cETLus safety mark for:
- General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
cULus safety mark
- General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Enclosure Rating: IP66 / NEMA 4X
Length: 181 mm
Manual Languages: Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Material Enclosures: Polycarbonate
Aluminium (powder coated)
Stainless steel
Mounting Configurations: Wall, pole, and panel mounting
Operating temperature range: -20 - 60 °C at 0 - 95% RH (non-condensing)
Power Options: 100-240V AC, US Power Cord
Power requirements (Hz): 50 - 60 Hz
Power requirements (Voltage): 100 - 240 VAC
Power supply: 100-240 V AC with US power cord
Relay: Operational Mode: Primary or secondary measurement, calculated value (dual channel only) or timer
Relay Functions: Scheduler (timer), alarm, feeder control, event control, pulse width modulation, frequency control, and warning
Relays: Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Security Levels: 2 password-protected levels
Sensor Input #1: 4-20mA Input
Sensor Input #2: Analog Conductivity
Storage conditions: -20 °C to 70 °C
Weight: 1.70 kg
What's included?: Controller, Mounting Hardware, Basic User Manual