Understanding Alkalinity in Water

Alkalinity measures the capacity of water to neutralize acids and maintain a stable pH level. It is an important water quality indicator across a variety of applications including drinking water , beverages, boiler/cooling water and wastewater treatment

High alkalinity water can:

  • Mitigate heavy metal's toxicity by using available bicarbonates and carbonates to remove metals from solutions.
  • Create an objectionable carbonated taste in drinking water and can be harmful to human health
  • Cause scaling or mineral build-up in industrial equipment and pipes

Low alkalinity water can:

  • Make streams, rivers or lakes vulnerable to acidic pollutants which can drop the pH(link) of water to levels harmful for amphibians, fish or zooplankton
  • Hinder the nitrification (links) process in biological wastewater treatment

Due to alkalinity's wide-ranging impacts, consistently monitor alkalinity is vital to maintaining healthy and stable water. Hach ® offers a wide range of testing equipment, resources, and software you need to successfully monitor alkalinity in your specific process application.

 

Featured Alkalinity Products

EZ Series Alkalinity Analyzers

EZ Series Alkalinity Analyzers

Applications: Influent for Wastewater, Primary Treatment, Secondary Treatment, drinking water, steam & power generation, surface water

These analyzers measure free (P-alkalinity) or Total Alkalinity, offering precise measurements of alkalinity in water samples. Guaranteed quick and accurate results

Discover More

S1000 Portable Parallel Analyser (PPA)

S1000 Portable Parallel Analyser (PPA)

Applications: Boiler Water, Cooling Water. Groundwater, Membrane Protection, Municipal Water, Potable Water, QA/QC Lab, Source Water, Surface Water

With its ability to perform multiple tests simultaneously, the SL1000 streamlines alkalinity measurement alongside other parameters, offering on-the-go analysis for field applications like water quality assessments and environmental monitoring.

Discover More

Titralab ® AT1000 & KF1000 Series

Titralab® AT1000 & KF1000 Series

Applications: Influent for Wastewater, Primary Treatment, Secondary Treatment, Surface Water

Utilizing precise titration techniques, volumetric titration methods like those used in the AT1000 and KF1000 series ensure reliable measurement of alkalinity levels, crucial for maintaining optimal conditions in industrial processes and environmental monitoring.

Discover More

Spectrophotometers

Spectrophotometers

Applications: Groundwater, Influent for Wastewater, Municipal Water, Nutrient Monitoring, Primary Treatment, QA/QC Lab, Secondary Treatment, Surface Water, Membrane Protection, Pre-Treatment, Production Water, Potable Water

Hach has been innovating with spectrophotometry for over 70 years and offers many of the leading spectrophotometers in the water analysis market. These instruments enable the quantification of alkalinity through colorimetric methods, allowing for highly accurate and sensitive measurements essential in research, quality control, and regulatory compliance across industries.

Discover More

Test Strips

Test Strips

With the simplicity and accuracy of Hach's alkalinity test kits, you can effortlessly ensure proper alkalinity levels in various field applications using drop count titration and color disc methods. Test strips are perfect for rapid on-site testing of alkalinity levels in water. Hach Total Alkalinity Test Strips provide a quick and easy way to estimate alkalinity levels in various water sources.

Discover More

 

Resources

Alkalinity in Drinking Water

Alkalinity in Drinking Water

Online measurement ensures drinking water quality by accurately monitoring the alkalinity, mitigating scaling or corrosion risks at Sydvatten Vomb drinking water treatment plant. Download our application note on cooling cycle analysis for further insights.

know More
Webinar

Webinar

Back to Basics - Hardness and Alkalinity Management within Source Water Vulnerability

Watch Now

 

 

Which Processes Require pH Monitoring?


Wastewater Treatment

In wastewater treatment, alkalinity is an important parameter in determining the health and stability of various biological treatment processes. In anaerobic digestion, alkalinity and its ratio to the concentration of volatile fatty acids (VFAs) is the most important measurement for understanding the stability of this biological process. For optimal results, a digester should have a pH value between 6.5 and 7.5. However, just measuring the pH is not enough. In order to ensure sustainable and safe operation, the water must have a sufficient buffering capacity in order to compensate for changes in the acid concentration. A digester that is too acidic is toxic for the bacteria, especially for the methane-producing bacteria. Upsets due to the toxic conditions of low pH can be very costly due to reduced gas production, chemical addition for alkalinity, and significant increase in staff time and effort. Re-seeding an upset digester can take weeks and is very time consuming. In systems that are required to remove ammonia nitrogen, alkalinity is a key monitoring parameter for stable nitrification. Alkalinity values below 50 mg/L will inhibit the biological conversion of ammonia/ammonium to nitrite then to nitrate. Once alkalinity is depleted in a biological system, pH can begin to rapidly decline. When monitoring aerated biological nitrogen removal, pH is a commonly used and helpful indicator of system nitrification stability, but it is a lagging indicator. For maximum system stability monitoring, alkalinity monitoring is a good predictive measurement to indicate issues before they become critical.

Wastewater Treatment

Drinking Water Treatment

Alkalinity acts as a pH buffer in coagulation and lime-soda softening of water. Alkalinity is monitored throughout the water treatment process and in the distribution system to ensure the delivery of safe drinking water to the community. Knowing raw water alkalinity is very important for choosing the correct coagulants and setting up coagulation/flocculation process. With the correct knowledge of all critical parameters, coagulation process may be enhanced to remove total organic carbon (TOC) and reduce disinfection by-products (DBP) formation potential in the water prior to chlorination. Alkalinity of filtered water is often adjusted to control its corrosivity prior to release in the distribution system and measuring alkalinity of the tap water in the distribution network is important to ensure adequate corrosion control and avoid violation of the lead and copper rule (LCR).

Drinking Water Purification

Beverage Industry

Besides monitoring alkalinity in the feed water for boilers and cooling towers, this parameter is vital for evaluation of the source water used for production, because wrong or inconsistent alkalinity can adversely affect flavor and overall quality of beer, juices and other beverages.

Boiler Water Applications

Chemical Manufacturing for Industrial Processes

Along with other parameters, alkalinity is monitored during cooling processes to prevent corrosion to piping, condensers and dryers over time. Monitoring alkalinity, along with other key parameters during industrial wastewater treatment, helps facilities ensure compliance with chemical industry regulations, avoid permit violations, maximize efficiency, control cost, and operate at the highest possible levels of health and safety.

Chemical Manufacturing for Industrial Processes

 

Processes Requiring Alkalinity Monitoring

Titration

AT1000-Digital-Titrationr

AT1000 Digital Titration

Everything you need for Alkalinity titration in one package.

Contact Us

Colorimetric Method

Alkalinity-Total-TNTplus-Vial-24

Alkalinity (Total) TNTplus Vial

Alkalinity TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For photometric determination of total alkalinity in drinking water, wastewater, and boiler water.

Contact Us
SL1000

SL1000 Portable Parallel Analyzers (PPA)

The SL1000 performs multiple standard tests and make data management easy. SL1000 Portable Parallel Analyzer (PPA) performs the same tests with less than half the manual steps. Get highly accurate results, with less opportunity for errors, in a fraction of the time.

Contact Us

Test Strips/Test Kits

Alkalinity-Total-TNTplus-Vial-24

Digital Titrator Test Kits

Hach digital titrators use a high-precision dispensation device and replaceable titrant cartridges for highly accurate results in the field or lab. More than 50 different paramaters and/or ranges are available to suit many testing applications.

Contact Us
SL1000

Total Alkalinity Test Strips

Detects carbonates, bicarbonates, hydroxides, and salts. Ideal for drinking water, food processing, boilers, and aquatic biology. 50 tests per kit. Easy, disposable, and cost-effective for quick, quantitative results in the field or lab.

Contact Us

 

Frequently Asked Questions

What is the difference between hardness and alkalinity?

Hardness is the sum of the multivalent metal ions in solution, whereas alkalinity is a measure of the solution’s ability to neutralize acids (sum of hydroxide, carbonate and bicarbonate ions). In natural water systems, calcium carbonate is usually present and responsible for different characteristics of the water. Both hardness and alkalinity are expressed as a concentration of CaCO 3 for convenience of reporting a single number to represent multiple chemicals, and for ease in calculating a solution’s carbonate and non-carbonate hardness.

What is the sample's alkalinity if the phenolphthalein indicator does not turn the sample pink?

Phenolphthalein alkalinity determination by titration uses a phenolphthalein indicator that changes from pink to colorless at the endpoint. If the sample does not turn pink after adding the indicator, the sample does not have phenolphthalein alkalinity. The sample will not have any phenolphthalein alkalinity if its pH is less than 8.3.

What are the interferences for Total Alkalinity, Colorimetric Method, TNTplus 870, Method 10239?

Samples with an acid capacity above 8 mmol/L must be diluted with deionized (DI) water that contains no carbon dioxide (CO 2). One can remove CO 2 from deionized water by boiling. The absence of CO 2 in the water used for dilution can be checked by carrying out a blank measurement. If the samples have high buffering capacity, dilute with DI water. CO 2 in the DI water will interfere when diluting samples or standards for this colorimetric test. The CO 2 free water is not as critical in the titration vs. the colorimetric procedure. The colorimetric test is more sensitive to slight changes in CO 2 concentration due to the colorimetric detection method and small sample volume used.

What are some common interferences in the alkalinity titration methods?

Some common interferences in alkalinity titration methods include:

  • Chlorine – Chlorine at levels above 3.5 mg/L can cause a yellow-brown color when the Bromcresol Green-Methyl Red Powder Pillow is added. To remove the interference, pretreat the sample by adding 1 drop of Sodium Thiosulfate Standard Solution, 0.1 N per 100 mL sample, before adding any other reagents.
  • Color or turbidity – Color or turbidity can make it difficult to see the color change at the endpoint. Do not filter or dilute samples with color or turbidity. Use a pH meter and titrate the samples to the specified endpoints:

    Sample composition Phenolphthalein alkalinity  Total alkalinity 
    Alkalinity approximately 30 mg/L pH 8.3 pH 4.9
    Alkalinity approximately 150 mg/L pH 8.3 pH 4.6
    Alkalinity approximately 500 mg/L pH 8.3 pH 4.3
    Contains silicates or phosphates pH 8.3 pH 4.5
    Industrial wastes or complex systems pH 8.3 pH 4.5
    Routine or automated analysis  pH 8.3 pH 4.5
  • Soaps, oily matter, suspended solids and precipitates – Oils or solids can collect on the pH probe and cause a slow response. Clean the probe immediately after use.

Can both alkalinity and hardness be measured together?

Yes, both alkalinity and hardness can be measured together using appropriate testing methods and equipment.

Download our application note on cooling cycle analysis to learn more about measuring alkalinity and hardness in water treatment processes.

Download

What is the difference between Total Alkalinity vs. Phenolphthalein Alkalinity

Total Alkalinity

Total alkalinity is a measure in parts per million of all the alkali (all carbonate, bicarbonate and hydroxide ions) present in a sample. Therefore, total alkalinity is a measurement of water's ability to resist changes in pH.

Total alkalinity is determined by titration to a pH of 4.9, 4.6, 4.5, or 4.3, depending on the amount of carbon dioxide present.

Phenolphthalein Alkalinity

Phenolphthalein alkalinity (p-alkalinity) is determined by titration to a pH of 8.3 (the end point when phenolphthalein indicator changes color) and it registers the total hydroxide and one half the carbonate present. Phenolphthalein alkalinity is a subset of total alkalinity.

Typically, hard water is alkaline, while soft water is more acidic. However, exceptions exist in unusual circumstances.

What compounds contribute to alkalinity?

Alkalinity in water is primarily influenced by compounds like bicarbonates, carbonates, and hydroxides of calcium, magnesium, and sodium. These substances act as buffers against pH changes, ensuring water stability. Hach offers comprehensive solutions for accurately measuring and managing alkalinity levels, empowering industries to maintain water quality standards effectively