Accuracy 2:
VELOCITY MEASUREMENT: ±2% of reading or 0.05 fps** **Uniform velocity profile, known salinity, positive flow. Field performance is site specific.
Accuracy 3:
LEVEL MEASUREMENT: ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC) ±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF); ±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF)
Accuracy 4:
Velocity-Induced Depth Error Compensated based on flow velocity
Allowable Level:
Standard: 10.5 m (34.5 ft)
Extended: 31.5 m (103.5 ft)
Cable:
Noryl® outer shell with epoxy potting within
Cable Length:
30.48 m
Compatible Instruments:
920, 930, 930T, 950, 900 Max Samplers, and AV9000 Interface Analyzer Module
Depth: Operating Unit:
Typical Minimum Operating Depth 2 cm
Dimensions (H x W x D):
23 mm x 38 mm x 135 mm
Level Accuracy:
±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC)
±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF)
±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF)
Level Measurement Method:
Differential pressure transducer with stainless steel diaphragm and atmospheric pressure reference
Level Range:
Standard: 0–3 m Extended: 0–9 m
Material:
Noryl® outer shell with epoxy potting within
Oil or Non-Oil Filled:
Non-oil filled with connector
Operating temperature range:
0 - 70 °C
Recommended Range:
-1.52 to 6.10 m/s (-5 to 20 ft/sec)
Special Feature:
Non-oil Filled, 100 ft cable
Typical Minimum Operating Depth:
2 cm (0.8cm)
Velocity Accuracy:
±2% of reading or 0.05 fps**
**Uniform velocity profile, known salinity,
positive flow. Field performance is site specific.
Velocity-Induced Depth Error:
Compensated based on flow velocity
Velocity Measurement Method:
Doppler ultrasonic;
twin 1 MHz piezoelectric crystals
Warranty:
12 months