Prices Online Include GST          1300 887 735

Ampule Breaker Kit, Voluette« Ampules

Ampule Breaker Kit, Voluette« Ampules
Product #: 2196800
Unit Price Contact Hach

Parameter/Range/Reagent Information

Alkalinity Method Range Reagent Set(s) USEPA Compliant?
  10239 TNTplus 25 - 400 mg/L as CaCO₃ View  
  8221 Buret Titration Method 0 - 5,000 mg/L CaCO₃ View Y
Aluminum Method Range Reagent Set(s) USEPA Compliant?
  8012 Aluminon Method, Powder Pillows 0.02 - 0.80 mg/L Al₃+ View  
  8012 Colorimeters, Powder Pillows 0.01 - 0.80 mg/L Al₃+ View  
  8012 Spectrophotometer, Powder Pillows 0.008 - 0.800 mg/L Al View  
  8326 Eriochrome Cyanine R 0.006 - 0.250 mg/L Al View  
Ammonia Method Range Reagent Set(s) USEPA Compliant?
  10023 Test 'N Tube LR Salicylate 0.02 - 2.50 mg/L NH3-N View  
  10031 Test 'N Tube HR Salicylate 0.4 - 50.0 mg/L NH3-N View  
  8038 Nessler 0.02 - 2.50 mg/L NH₃-N View Y
  8155 Powder Pillows Salicylate 0.01 - 0.50 mg/L NH₃-N View  
Ammonia, Free Method Range Reagent Set(s) USEPA Compliant?
  10200 Chloramine (Mono) and Nitrogen, Free Ammonia Powder Pillows, Pocket Colorimeter II 0.02 - 0.50 mg/L NH₃-N View  
  10200 Spectrophotometer Powder Pillows 0.01 - 0.50 mg/L NH₃-N View  
Bromine Method Range Reagent Set(s) USEPA Compliant?
  8016 DPD Method, PP or AccuVac 0.05 - 4.50 mg/L Br₂ View  
Carbon Dioxide Method Range Reagent Set(s) USEPA Compliant?
  8205 10 - 1,000 mg/L CO₂ View  
  8205 10 - 100 mg/L View  
  8233 0 - 250 mg/L CO₂ View  
Chloride Method Range Reagent Set(s) USEPA Compliant?
  8113 0.1 - 25.0 mg/L Cl⁻ View  
  8206 Digital Titration Mercuric Nitrate 10 - 8,000 mg/L Cl View Y
  8207 Digital Titration Silver Nitrate 10 - 10,000 mg/L Cl View  
  8207 Digital Titration Silver Nitrate 10 - 100 mg/L Cl View  
  8207 Digital Titration Silver Nitrate 100 - 10,000 mg/L Cl View  
  8225 Buret Titration 0 - 25,000 mg/L Cl- View  
Chlorine Demand / Requirement Method Range Reagent Set(s) USEPA Compliant?
  10223 Chlorine Demand/Requirement 10223 varies View  
Chlorine Dioxide Method Range Reagent Set(s) USEPA Compliant?
  10126 DPD 0.05 - 5.00 mg/L ClO₂ View Y
  10126 DPD Powder Pillows or AccuVac 0.04 - 5.00 mg/L ClO2 View Y
Chlorine, Free Method Range Reagent Set(s) USEPA Compliant?
  10059 DPD Rapid Liquid Method, Pour-Thru Cell™ DPD Rapid Liquid Method for Free Chlorine 0.02 - 2.00 mg/L Cl₂ View  
  10069 DPD, HR Powder Pillows 0.1 - 10.0 mg/L Cl2 View  
  10102 DPD Test 'N Tube 0.09 - 5.00 mg/L Cl2 View  
  10231 Spectrophotometer,TNTplus DPD 0.05 - 2.00 mg/L Cl2 View Y
  10241 Powder Pillows Indophenol 0.04 - 4.50 mg/L Cl₂ View  
  10245 DPD, MR Powder Pillows 0.05 - 4.00 mg/L Cl2 View  
  8021 DPD Powder Pillows or AccuVac® 0.02 - 2.00 mg/L Cl2 View Y
  8334 Amperometric Buret Titration Method 0.5 mg/L and above Cl₂ View Y
  Chemkeys for PPA - Free Chlorine ChemKeys for PPA - Free Chlorine 0.04 - 4.00 mg/L Cl2 View Y
  DPD PCII DR300 SwifTest Dispenser 0.1 - 8.0 mg/L Cl2 View  
Chlorine, Free & Total Method Range Reagent Set(s) USEPA Compliant?
  8210 DPD-FEAS Digital Titrator 0 - 3.00 mg/L Cl₂ View  
  DR300 Pocket Colorimeter DPD, High Range DPD 0.1 - 8.0 mg/L Cl₂ View Y
  PCII DR300 USEPA DPD, Mid-Range 0.05 - 4.00 mg/L Cl₂ View  
  Pocket Colorimeter DPD, High Range 0.1-10 0.1 - 10 mg/L Cl₂ View  
Chlorine, Total Method Range Reagent Set(s) USEPA Compliant?
  10060 DPD Rapid Liquid, Pour-Thru Cell 0.02 - 2.00 mg/L Cl₂ View  
  10070 DPD Powder Pillows 0.1 - 10.0 mg/L as Cl₂ View Y
  10101 DPD Test 'N Tube 0.09 - 5.00 mg/L Cl₂ View  
  10232 Spectrophotometer DPD TNTplus DPD 0.05 - 2.00 mg/L Cl2 View Y
  10250 DPD Powder Pillows 0.05 - 4.00 mg/L Cl2 View Y
  8167 DPD Powder Pillows or AccuVac® 0.02 - 2.00 mg/L Cl₂ View Y
  8168 Amperometric Buret Titration Method 0.0012 - 5,000 mg/L Cl₂ View Y
  8168 WAH, Amperometric Buret Titration 0.5 - mg/L and above View Y
  8209 Iodometric Method 2,000 - 70,000 mg/L CL₂ View  
  8209 Iodometric Method 20 - 2,000 mg/L Cl₂ View  
  8209 WAH, Iodometric, Digital Titration 1 - 400 mg/L Cl₂ View  
  8209 WAH, Iodometric, Digital Titration 20 - 70,000 mg/L View  
  8370 DPD 2 - 500 µg/L - as Cl₂ View Y
  DPD HR PCII DR300 SwifTest Dispenser 0.1 - 8.0 mg/L Cl2 View  
Chromium, Hexavalent Method Range Reagent Set(s) USEPA Compliant?
  8023 1,5-Diphenylcarbohydrazide 0 - 1.00 mg/L Cr6+ View Y
  8023 Powder Pillows or AccuVac® 0.010 - 0.700 mg/L Cr6+ View Y
Copper Method Range Reagent Set(s) USEPA Compliant?
  8026 CuVer 2 AccuVac® Bicinchoninate 0.04 - 5.00 mg/L Cu View  
  8506 CuVer 1 Powder Pillows Bicinchoninate 0.04 - 5.00 mg/L Cu View Y
Formaldehyde Method Range Reagent Set(s) USEPA Compliant?
  8110 MBTH 3 - 500 µg/L CH2O View  
Hardness Method Range Reagent Set(s) USEPA Compliant?
  8204 Calcium Hardness Digital Titration EDTA 10 - 4,000 mg/L as CaCO₃ View  
  8222 Buret Titration 100 - 25,000 mg/L CaCO₃ View  
  8226 ManVer Buret Titration 0 - 2,500 mg/L CaCO₃ View Y
  8329 Digital Titration EDTA 10 - 160 mg/L CaCO3 View  
  8329 Digital Titration EDTA 10 - 4,000 mg/L CaCO3 View  
Iodine Method Range Reagent Set(s) USEPA Compliant?
  8031 Spectrophotometer, Powder Pillows or AccuVac DPD 0.07 - 7.00 mg/L I₂ View  
Iron Method Range Reagent Set(s) USEPA Compliant?
  8112 PCII DR300 Powder Pillows AccuVac 0.01 - 1.70 mg/L Fe View  
  8214 Digital Titration 10 - 100 mg/L Fe View  
  8214 Digital Titration 100 - 1,000 mg/L Fe View  
Lead Method Range Reagent Set(s) USEPA Compliant?
  8033 Spectrophotometer Powder Pillows Dithizone 3 - 300 µg/L Pb View Y
Manganese Method Range Reagent Set(s) USEPA Compliant?
  8034 Powder Pillows Periodate Oxidation 0.1 - 20.0 mg/L Mn View Y
  8149 PAN 0.01 - 0.70 mg/L Mn View  
  8149 Powder Pillows PAN Method 0.006 - 0.700 mg/L Mn View  
Monochloramine Method Range Reagent Set(s) USEPA Compliant?
  10171 Indophenol LR, Powder Pillows 0.04 - 4.50 mg/L Cl₂ View  
  10200 Monochloramine/Free Ammonia Powder Pillows 0.01 - 0.50 mg/L NH₃-N View  
  10200 Monochloramine/Free Ammonia Powder Pillows 0.04 - 4.50 mg/L Cl2 View  
  Chemkeys for PPA - Monochloramine ChemKeys for PPA - Monochloramine 0.04 - 4.00 mg/L Cl₂ View  
Nitrate Method Range Reagent Set(s) USEPA Compliant?
  10020 Spectrophotometer, Test 'T Tube Chromotropic Acid Method 0.2 - 30.0 mg/L NO3--N View  
  10049 Spectrophotometer, UV Screening UV Screening 0.1 - 10.0 mg/L View  
Nitrogen, Total Method Range Reagent Set(s) USEPA Compliant?
  10071 Test 'N Tube LR Persulfate Digestion 0.5 - 25.0 mg/L N View  
  10072 DR800 HR Test 'N Tube 10 - 150 mg/L N View  
  10208 Spectrophotometer HR TNTplus 5 - 40 mg/L N View  
  10208 Spectrophotometer LR TNTplus 1 - 16 mg/L N View  
  10208 Spectrophotometer UHR TNTplus 20 - 100 mg/L N View  
Phosphonates Method Range Reagent Set(s) USEPA Compliant?
  8007 Powder Pillows Persulfate UV Oxidation 0.02 - 2.50 mg/L PO43- View  
  8007 Powder Pillows Persulfate UV Oxidation 0.1 - 2.5 mg/L View  
  8007 Powder Pillows Persulfate UV Oxidation 1.0 - 125 mg/L PO43- View  
Phosphorus Method Range Reagent Set(s) USEPA Compliant?
  10055 Spectrophotometer Pour-Thru Cell 19 - 3,000 µg/L PO₄ View  
  10127 Test 'N Tube Molybdovanadate with Acid Persulfate Digestion 1.0 - 100.0 mg/L PO4 View  
  10209 Spectrophotometer HR, TNTplus 844 0.5 - 5 mg/L P (1.5-15.0 mg/L PO₄) View Y
  10209 Spectrophotometer LR, TNTplus 843 0.05 - 1.5 mg/L P (0.15-4.5 mg/L PO₄) View Y
  10209 Spectrophotometer UHR, TNTplus 845 2 - 20 mg/L P (6-60 mg/L PO₄) View Y
  10214 Spectrophotometer TNTplus 846 1.6 - 30 mg/L P (5.0 - 90 mg/L PO₄) View  
  8048 Powder Pillows or AccuVac® PhosVer 3, Ascorbic Acid 0.02 - 2.50 mg/L PO4 View Y
  8048 TNT™ PhosVer 3 0.06 - 5.00 mg/L PO4 ³⁻ View Y
  8114 Reagent or AccuVac Molybdovanadate 0.3 - 45.0 mg/L PO4 View  
  8114 Test 'N Tube HR Molybdovanadate 1.0 - 100.0 mg/L PO4 View  
  8178 Amino Acid Reagent Amino Acid Method 0.23 - 30.00 mg/L PO4 View  
  8190 Digestion Test 'N Tube™ 0.06 - 3.50 mg/L PO4 View Y
Potassium Method Range Reagent Set(s) USEPA Compliant?
  8049 Spectrophotometer Powder Pillows 0.1 - 7.0 mg/L K View  
Salinity Method Range Reagent Set(s) USEPA Compliant?
  10073 Digital Titration 0 - 100 ppt salinity View  
Sulfate Method Range Reagent Set(s) USEPA Compliant?
  8051 Powder Pillows or AccuVac® SulfaVer 4 2 - 70 mg/L SO42- View Y
Sulfite Method Range Reagent Set(s) USEPA Compliant?
  8071 0 - 500 mg/L SO₃²¯ View  
  8216 Iodate-Iodide Digital Titration 4 - >400 mg/L SO32- View  
TKN Method Range Reagent Set(s) USEPA Compliant?
  8075 TKN, Nessler 1 - 150 mg/L TKN View  
Trihalomethane Formation Potential (THMFP) Method Range Reagent Set(s) USEPA Compliant?
  10224 1,190 - 1,310 mg/L as Cl₂ View  
Volatile Acids Method Range Reagent Set(s) USEPA Compliant?
  10240 TNTplus 50 - 2,500 mg/L Acetic View  
  8196 Reagent Solution Esterification 27 - 2800 mg/L as Acetic Acid View  
Zinc Method Range Reagent Set(s) USEPA Compliant?
  8009 Powder Pillows Zincon 0.01 - 2.00 mg/L Zn View Y
  8009 Powder Pillows Zincon 0.01 - 3.00 mg/L Zn View Y