Prices Online Include GST          1300 887 735

COD Vial Adapter

COD Vial Adapter
Product #: 4846400
Unit Price Contact Hach

Parameter/Range/Reagent Information

Ammonia Method Range Reagent Set(s) USEPA Compliant?
  10023 DR800 Test "N Tube 0 - 2.50 mg/L NH3-N View  
  10023 Test 'N Tube LR Salicylate 0.02 - 2.50 mg/L NH3-N View  
  10031 DR800 Test 'N Tube 0 - 50 mg/L NH3-N View  
  10031 Test 'N Tube HR Salicylate 0.4 - 50.0 mg/L NH3-N View  
Boron Method Range Reagent Set(s) USEPA Compliant?
  10252 Carmine Method Powder Pillows 2 - 50 mg/L B View  
Chlorine, Free Method Range Reagent Set(s) USEPA Compliant?
  10102 DPD Test 'N Tube 0.09 - 5.00 mg/L Cl2 View  
  10102 DR800, Test 'N Tube DPD 0 - 5.00 mg/L    
Chlorine, Total Method Range Reagent Set(s) USEPA Compliant?
  10101 DPD Test 'N Tube 0.09 - 5.00 mg/L Cl₂ View  
  10101 DR800, DPD Test 'N Tube DPD 0 - 5.00 mg/L    
COD (Chemical Oxygen Demand) Method Range Reagent Set(s) USEPA Compliant?
  10067 Manganese III, without Cl2 removal, DR800 20 - 1,000 mg/L View  
  8000 DR800 LR, MR, HR 0 - 1,500 mg/L COD View Y
  8000 DR800 LR, MR, HR 0 - 15,000 mg/L View  
  8000 DR800 LR, MR, HR 0 - 150 mg/L COD View Y
  8000 Reactor Digestion 0.7 - 40.0 mg/L View  
  8000 Reactor Digestion 20 - 1500 mg/L View Y
  8000 Reactor Digestion 200 - 15,000 mg/L View  
  8000 Reactor Digestion 3 - 150 mg/L View Y
Monochloramine Method Range Reagent Set(s) USEPA Compliant?
  10172 DR800 Test 'N Tubes 0 - 10.0 mg/L Cl2 View  
  10172 Indophenol Method Test 'N Tube 0.1 - 10.0 mg/L Cl₂ View  
Nitrate Method Range Reagent Set(s) USEPA Compliant?
  10020 DR800, Test "N Tube 0 - 30.0 mg/L View  
Nitrite Method Range Reagent Set(s) USEPA Compliant?
  10019 DR800, LR, Test 'N Tube 0 - 0.500 mg/L NO2--N View  
  10019 Test 'N Tube Vials Diazotization 0.003 - 0.500 mg/L NO2--N View  
Nitrogen, Total Method Range Reagent Set(s) USEPA Compliant?
  10071 DR800, Test 'N Tube 0.0 - 25.0 mg/L N View  
  10071 Test 'N Tube LR Persulfate Digestion 0.5 - 25.0 mg/L N View  
  10072 DR800 HR Test 'N Tube 10 - 150 mg/L N View  
  10072 Test 'N Tube HR Persulfate Digestion 2 - 150 mg/L N View  
Nitrogen, Total Inorganic (TIN) Method Range Reagent Set(s) USEPA Compliant?
  10021 DR800, Test 'N Tube 0 - 25.0 mg/L N View  
  10021 Test 'N Tube™ Titanium Trichloride Reduction 0.2 - 25.0 mg/L N View  
Phosphorus Method Range Reagent Set(s) USEPA Compliant?
  10127 DR800 Test 'N Tube 0.0 - 100.0 mg/L PO4 3- View  
  10127 Test 'N Tube Molybdovanadate with Acid Persulfate Digestion 1.0 - 100.0 mg/L PO4 View  
  8048 DR800 Test 'N Tube 0.00 - 5.00 mg/L PO4 3- View Y
  8048 TNT™ PhosVer 3 0.06 - 5.00 mg/L PO4 ³⁻ View Y
  8114 DR800 Test 'N Tube 0.0 - 100.0 mg/L PO4 3- View  
  8114 Test 'N Tube HR Molybdovanadate 1.0 - 100.0 mg/L PO4 View  
  8180 DR800 Acid Hydolysis, Test 'N Tube 0.00 - 5.00 mg/L PO4 3- View  
  8180 Test 'N Tube™ PhosVer® 3 with Acid Aydrolysis 0.06 - 3.50 mg/L PO4 View  
  8190 Digestion Test 'N Tube™ 0.06 - 3.50 mg/L PO4 View Y
  8190 DR800 Digestion Test 'N Tube 0.00 - 3.50 mg/L PO4 3- View Y
Total Organic Carbon (TOC) Method Range Reagent Set(s) USEPA Compliant?
  10128 HR, Colorimeter Test 'N Tube Direct 20 - 700 mg/L C View  
  10129 LR, Test 'N Tube Direct 0.3 - 20.0 mg/L C View  
  10173 MR, Test 'N Tube Direct 15 - 150 mg/L C View  
Toxicity Method Range Reagent Set(s) USEPA Compliant?
  10017 DR800 ToxTrak Toxicity (ToxTrak™) 10017 % Inhibition View