Chemistries                 1300 887 735

Cooling rack for 10 cuvettes (Ø 16 mm), stainless steel

Cooling rack for 10 cuvettes (Ø 16 mm), stainless steel
Product #: 1864100
Unit Price Contact Hach

Parameter/Range/Reagent Information

Ammonia Method Range Reagent Set(s) USEPA Compliant?
  10023 DR800 Test "N Tube 0 - 2.50 mg/L NH3-N View  
  10031 DR800 Test 'N Tube 0 - 50 mg/L NH3-N View  
  10031 Test 'N Tube HR Salicylate 0.4 - 50.0 mg/L NH3-N View  
Anammox Activity Method Range Reagent Set(s) USEPA Compliant?
  10304 TNTplus 882 0 - 1000 mAbs (milli absorptions) View  
  10304 TNTplus 882 0 - 33.4 µmol/L (Cytochrome C from horse heart) View  
Chlorine, Free Method Range Reagent Set(s) USEPA Compliant?
  10102 DPD Test 'N Tube 0.09 - 5.00 mg/L Cl2 View  
Chlorine, Total Method Range Reagent Set(s) USEPA Compliant?
  10101 DPD Test 'N Tube 0.09 - 5.00 mg/L Cl₂ View  
Chromium, Hexavalent and Total Method Range Reagent Set(s) USEPA Compliant?
  10218 Hexavalent, TNTplus 0.03 - 1.00 mg/L Cr View Y
  10219 Total, TNTplus 0.03 - 1.00 mg/L Cr View Y
COD (Chemical Oxygen Demand) Method Range Reagent Set(s) USEPA Compliant?
  10067 (Manganese III without chloride removal) Spectrophotometer Manganese III Reactor Digestion Method 30 - 1,000 mg/L View  
  10067 Manganese III, without Cl2 removal, DR800 20 - 1,000 mg/L View  
  10211 TNTplus ULR 1.0 - 60.0 mg/L View  
  8000 DR800 LR, MR, HR 0 - 1,500 mg/L COD View Y
  8000 DR800 LR, MR, HR 0 - 15,000 mg/L View  
  8000 DR800 LR, MR, HR 0 - 150 mg/L COD View Y
  8000 Reactor Digestion 0.7 - 40.0 mg/L View  
  8000 Reactor Digestion 20 - 1500 mg/L View Y
  8000 Reactor Digestion 200 - 15,000 mg/L View  
  8000 Reactor Digestion 3 - 150 mg/L View Y
Formaldehyde Method Range Reagent Set(s) USEPA Compliant?
  10295 Formaldehyde TNTplus 0.5 - 10.0 mg/L H₂CO View  
Monochloramine Method Range Reagent Set(s) USEPA Compliant?
  10172 DR800 Test 'N Tubes 0 - 10.0 mg/L Cl2 View  
  10172 Indophenol Method Test 'N Tube 0.1 - 10.0 mg/L Cl₂ View  
Nitrate Method Range Reagent Set(s) USEPA Compliant?
  10020 DR800, Test "N Tube 0 - 30.0 mg/L View  
  10020 Spectrophotometer, Test 'T Tube Chromotropic Acid Method 0.2 - 30.0 mg/L NO3--N View  
Nitrite Method Range Reagent Set(s) USEPA Compliant?
  10019 DR800, LR, Test 'N Tube 0 - 0.500 mg/L NO2--N View  
Nitrogen, Total Method Range Reagent Set(s) USEPA Compliant?
  10071 DR800, Test 'N Tube 0.0 - 25.0 mg/L N View  
  10071 Test 'N Tube LR Persulfate Digestion 0.5 - 25.0 mg/L N View  
  10072 DR800 HR Test 'N Tube 10 - 150 mg/L N View  
  10072 Test 'N Tube HR Persulfate Digestion 2 - 150 mg/L N View  
Nitrogen, Total Inorganic (TIN) Method Range Reagent Set(s) USEPA Compliant?
  10021 DR800, Test 'N Tube 0 - 25.0 mg/L N View  
  10021 Test 'N Tube™ Titanium Trichloride Reduction 0.2 - 25.0 mg/L N View  
Phosphorus Method Range Reagent Set(s) USEPA Compliant?
  10127 DR800 Test 'N Tube 0.0 - 100.0 mg/L PO4 3- View  
  10127 Test 'N Tube Molybdovanadate with Acid Persulfate Digestion 1.0 - 100.0 mg/L PO4 View  
  10209 Spectrophotometer HR, TNTplus 844 0.5 - 5 mg/L P (1.5-15.0 mg/L PO₄) View Y
  10209 Spectrophotometer LR, TNTplus 843 0.05 - 1.5 mg/L P (0.15-4.5 mg/L PO₄) View Y
  10209 Spectrophotometer UHR, TNTplus 845 2 - 20 mg/L P (6-60 mg/L PO₄) View Y
  10209 Spectrophotometer ULR, TNTplus 843 10 - 500 µg/L P (30-1500µg/L PO₄) View Y
  10210 Spectrophotometer LR, TNTplus 843 0.15 - 4.50 mg/L PO43- View  
  10210 Spectrophotometer UHR, TNTplus 845 Ascorbic Acid Method TNTplus™ 843 6 - 60 mg/L PO43- View  
  8048 DR800 Test 'N Tube 0.00 - 5.00 mg/L PO4 3- View Y
  8048 TNT™ PhosVer 3 0.06 - 5.00 mg/L PO4 ³⁻ View Y
  8114 DR800 Test 'N Tube 0.0 - 100.0 mg/L PO4 3- View  
  8114 Test 'N Tube HR Molybdovanadate 1.0 - 100.0 mg/L PO4 View  
  8180 DR800 Acid Hydolysis, Test 'N Tube 0.00 - 5.00 mg/L PO4 3- View  
  8180 Test 'N Tube™ PhosVer® 3 with Acid Aydrolysis 0.06 - 3.50 mg/L PO4 View  
  8190 Digestion Test 'N Tube™ 0.06 - 3.50 mg/L PO4 View Y
  8190 DR800 Digestion Test 'N Tube 0.00 - 3.50 mg/L PO4 3- View Y
Total Organic Carbon (TOC) Method Range Reagent Set(s) USEPA Compliant?
  10128 DR800, HR Direct 20 - 700 mg/L C View  
  10128 HR, Colorimeter Test 'N Tube Direct 20 - 700 mg/L C View  
  10128 HR, Spectrophotometer Test 'N Tube Direct 100 - 700 mg/L C View  
  10129 DR800, LR Direct 0.0 - 20.0 mg/L C View  
  10173 DR800, MR, TOC Direct 15 - 150 mg/L C View  
  10173 MR, Test 'N Tube Direct 15 - 150 mg/L C View  
  10267 HR Spectrophotometer TNTplus 811 30 - 300 mg/L C View  
  10267 LR Spectrophotometer TNTplus 810 1.5 - 30.0 mg/L C View  
Toxicity Method Range Reagent Set(s) USEPA Compliant?
  10017 ToxTrak 0 - 100 % Inhibition View  
Volatile Acids Method Range Reagent Set(s) USEPA Compliant?
  10240 TNTplus 50 - 2,500 mg/L Acetic View