Prices Online Include GST          1300 887 735

HQ40d Meter, PHC101 Standard pH Probe with 3 meter cable and CDC401 Standard Conductivity Probe with 3 meter cable

OBSOLETE ITEM

HQ40d Meter, PHC101 Standard pH Probe with 3 meter cable and CDC401 Standard Conductivity Probe with 3 meter cable
Product #: HQ40D53103203

OBSOLETE ITEM

Guided Calibrations

All Hach HQd Digital Meters provide an intuitive user interface with guided calibration and check standard routines to reduce calibration errors and simplify operation. Calibration status indicator and custom calibration alerts ensure accurate results.

Traceability and Reporting

HQd meters record probe serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log. Each measurement can be linked to sample ID, user ID, probe serial number, and more for complete traceability and regulator

Easy to Use in the Field

All connections between the meter and the probe are secure and waterproof. Connectors can be color-coded for quick identification. Information is clearly displayed on the one screen with back light for low light conditions. Display results can be enlarged.

Error-free O2 results without calibration or replacing the electrolyte

Rugged and waterproof meter design provides worry-free, reliable operation in field environments. All connections between the meter and the probe are secure. Connectors can be color-coded for quick identification. Information is clearly displayed on the one screen with back light for low light conditions. Display results can be enlarged.

Full GLP data management

Package content includes everything you need to start testing. Details below

What's included?

Meter package includes HQ40D Portable Meter; 4 AA batteries; Power adapter, USB/DC power adapter for data transfer; quick-start guide and user manual; Standard Field case; Protective Glove for Portable HQd Meter; 120 mL Sample Container (x5).
Intellical CDC401 Laboratory Conductivity Cell, 3 m cable, Test certificate, and Basic User Manual.Intellical.
Intellical PHC101 Laboratory pH electrode with storage soaker bottle, 3 m cable, Test certificate, and Basic User Manual.

Specifications

AC Power Adapter and USB/DC Adapter: Included
Automatic Buffer Recognition: Yes
Backlight:
Barometric Pressure Measurement: Automatic compensation of DO when using an LDO or LBOD probe
Calibration: Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder: Off, selectable from 2 hours to 7 days
Compliance Certifications: CE.WEEE
Conductivity measurement: Yes
Conductivity measurement: Temperature correction: None; Linear; NaCl Non-Linear Natural Water.
Conductivity Measurement Range: 0.01 µS/cm - 200.0 mS/cm
Conductivity resolution: 0.01 µS/cm - 0.1 mS/cm upon selected measuring range
Contents: No
Custom Calibration Standards: Yes
Data Export: Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
Data Memory: 500 records/FIFO
Data Storage: Automatic, GLP ISO compliant reading data stored with calibration details.
Digital (intelligent) electrode inputs: 2 channels
Display: Detailed mode/Large mode
Display Lock Function: Continuous / Auto-stabilization ("press to read") / At Interval
Display Type: 240 x 160 pixel LCD with backlight illumination
DO Measurement Range: 0.1 - 20.0 mg/L (ppm) 1 - 200% saturation
DO Resolution: 0.1
DO sensor calibration: * 100% (water-saturated air (100%) calibration
* 100% with 0 (water-saturated air (100%) calibration with 0 point
* mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution)
* mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point)
* Factory (calibration with the default LDO calibration)
GLP Features: Date; Time; Sample ID; Operator ID
Inputs: 2
Instrument: Portable
IP Rating: IP67
ISE Direct Measurement Range: Yes
ISE Electrode Calibration: 2 - 5 Points
Kit?: Yes
Languages: English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
Measurement method: Probe specific programmed method settings
Model: HQ40D – Multi/2 Channels
mV Measurement at Stable Reading: Yes
mV Measurement Range: -1500 - 1500 mV
mV Resolution: 0.1 mV
Needed Cable Length: 3
Operating Error Messages: Clear text error messages displayed
Operating Humidity: 90 % relative humidity (non-condensing)
Operating Interface: Soft Touch Keypad
Operating Temperature: 0 - 60 °C (32 - 140 °F)
ORP Electrode Calibration: Predefined ORP standards (including Zobell's solution)
Parameter: pH/Oxydo Reduction Potential (ORP)
Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity
Dissolved Oxygen (DO)
Biochemical Oxygen Demand (BOD)
Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium
Parameters: pH
Conductivity
NA
PC Data Transfer Software: HQD Series Meter Data Transfer Utility
pH Buffer Sets: IUPAC standards
(DIN 19266) or Technical buffer (DIN 19267) or 4-7-10 series or user defined
pH Electrode calibration: 1 - 3 Calibration points
Calibration summary data logged and displayed
pH Measurement Range: 0 - 14 pH
pH Resolution: Selectable:
0.001/0.01/0.1 pH
Printer: Yes, Optional
Probes included: PHC10103, CDC40103
Probe Type: Intellical Standard Laboratory or Rugged Field
Salinity Measurement Range: 0 - 42 (ppt) (‰)
Salinity Resolution: 0.01 (ppt) (‰)
Sensor A: PHC10103 (3 m)
Sensor B: CDC40103 (3 m)
Sensor C: NA
Sensors: Sensor A: PHC10103
Sensor B: CDC40103
Sensor C:
Simultaneous measurements: Yes, 2 channels
TDS Measurement Range: 0.00 mg/L - 50.0 g/L NaCl
TDS Resolution: 0.01 mg/L up - 0.1 g/L upon measuring range
Temperature Compensation: Automatic Temperature compensation for pH
  Automatic Temperature compensation for pH
Temperature Measurement: °C or °F
Temperature Resolution: 0.1
Type of measurement: Field Measurements
Warranty: 36 months
Weight: 335 g (0.75 lb) without batteries; 430 g (0.95 lb) with
What's included?: Meter package includes HQ40D Portable Meter; 4 AA batteries; Power adapter, USB/DC power adapter for data transfer; quick-start guide and user manual; Standard Field case; Protective Glove for Portable HQd Meter; 120 mL Sample Container (x5).
Intellical CDC401 Laboratory Conductivity Cell, 3 m cable, Test certificate, and Basic User Manual.Intellical.
Intellical PHC101 Laboratory pH electrode with storage soaker bottle, 3 m cable, Test certificate, and Basic User Manual.