Accuracy:
                                            
                                            
                                        
									    The greater of ±1% of reading, or ±0.03 ppb, or ±1 Pa (Membrane 2956A)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Accuracy 2:
                                            
                                            
                                        
									    The greater of ±1% of reading, or ±0.09 ppb, or ±6 Pa (Membrane 2952A)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Accuracy 3:
                                            
                                            
                                        
									    The greater of ±1% of reading, or ±1 ppb, or ±50 Pa (Membrane 2995A)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Accuracy 4:
                                            
                                            
                                        
									    The greater of ±1% of reading, or ±10 ppb, or ±1 kPa (Membrane 29015A)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Ambient Temperature:
                                            
                                            
                                        
									    -5 - 100 °C (23 - 212 °F)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Application:
                                            
                                            
                                        
									    Corrosion rate
                                    
                                
    						
								
                                    
                                        
                                            
                                                Certifications:
                                            
                                            
                                        
									    IP68 / NEMA4
                                    
                                
    						
								
                                    
                                        
                                            
                                                Flow Rate:
                                            
                                            
                                        
									    Typical Flow Rate
Membrane 2956A: 50 - 220 mL/min
Membrane 2952A: 40 - 200 mL/min
Membrane 2995A: 20 - 70 mL/min
Membrane 29015A: 20 - 40 mL/min
                                    
                                
    						
								
                                    
                                        
                                            
                                                Protection Class:
                                            
                                            
                                        
									    IP68 / NEMA4
                                    
                                
    						
								
                                    
                                        
                                            
                                                Purge connection:
                                            
                                            
                                        
									    None
                                    
                                
    						
								
                                    
                                        
                                            
                                                Radiation Resistance Level:
                                            
                                            
                                        
									    Membrane 2956A: 2x104  rad
Membrane 2952A: 108 rad
Membrane 2995A: 108 rad
Membrane 29015A: N/A
                                    
                                
    						
								
                                    
                                        
                                            
                                                Range:
                                            
                                            
                                        
									    Range at 25 °C 
Membrane 2956A: 0 - 75 ppb or 0 Pa - 5 kPa
Membrane 2952A: 0 - 300 ppb or 0 Pa - 20 kPa
Membrane 2995A: 0 - 3200 ppb or 0 Pa - 200 kPa
Membrane 29015A: 0 ppb - 32 ppm or 0 - 2000 kPa
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Pressure:
                                            
                                            
                                        
									    0 - 100 bar
                                    
                                
    						
								
                                    
                                        
                                            
                                                Temperature Range:
                                            
                                            
                                        
									    Accurate from -5 - 50 °C (23 - 122 °F)
Resistant - temperature from -5 - 100 °C (23 - 212 °F)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    6 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    140 - 700 g, depending on the construction material
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    Sensor only.
Controller, sensor cable, flow-chamber or process connection must be ordered separately.